Spaenaur Catalog 14 - Digital Flipping Catalog

CATALOG 14 C P : 1-800-265-8772 F : 1-888-252-6380 www. .com Inch Pouce Parawedge™ Data Sheet C117 20 NOV 2018 Fiche de données ParawedgeMD INSTALLATION INSTRUCTIONS TOOLS REQUIRED Installation instructions and warnings packaged with products must be followed preworking with all products. All test data provided were from tests performed to ASTME-488-81 and conducted in curing time designated in each chart. Ultimate values of tensile and shear loads shown in test data should be used purely as a guide. Actual results may vary and are dependent on such factors as concrete strength, concrete curing time, grade of steel, embedment depth, and proper installation. All drill sizes are per ANSI B212.15. Note: PARAWEDGE concrete anchors must be installed at the recommended spacing and edge distances to obtain full working load. General industry practice for static loads is to use a safety factor of 4:1 to obtain safe working loads. In all installations, it is recommended that tests to simulate actual conditions are to be carried out to determine the suitability of the products for a particular application. For technical information and product performance data, contact Spaenaur Sales Desk for details. NOTE: Installing in concrete that is cured for less than 28 days will greatly reduce the anchor's strength. WARNING: WEAR SAFETY GOGGLES ANCHOR SPACING (CENTER TO CENTER SPACING) To obtain the maximum tension and shear load, a spacing S = 12 anchor diameters (12d) should be used. When using the minimum recommended anchor spacing, S = 6 anchor diameters (6d) the load should be reduced by 50%. The following table lists the load reduction factor for each anchor diameter (d), based on the center to center anchor spacing. EDGE DISTANCE (CENTER TO EDGE SPACING) To obtain the maximum tension and shear load, an edge distance E = 12 anchor diameters (12d) should be used. When using the minimum recommended edge distance E = 6 anchor diameters (6d), the tension load should be reduced by 50% and the shear load by 20%. The following table lists the load reduction factor for each anchor diameter (d) based on the anchor center to edge distance. LENGTH IDENTIFICATION CODE Stamp on Anchor A B C D E F G H I J K L Anchor Size From: 1-1/2" 2" 2-1/2" 3" 3-1/2" 4" 4-1/2" 5" 5-1/2" 6" 6-1/2" 7" Up to: 2" 2-1/2" 3" 3-1/2" 4" 4-1/2" 5" 5-1/2" 6" 6-1/2" 7" 7-1/2" ANCHOR SPACING (S) in inches dia. = d 12d 11d 10d 9d 8d 7d 6d 1/4'' 3'' 2-3/4'' 2-1/2'' 2-1/4'' 2'' 1-3/4'' 1-1/2'' 5/16'' 3-3/4'' 3-3/8'' 3-1/8'' 2-7/8'' 2-1/2'' 2-1/4'' 1-7/8'' 3/8'' 4-1/2'' 4-1/8'' 3-3/4'' 3-3/8'' 3'' 2-5/8'' 2-1/4'' 1/2'' 6'' 5-1/2'' 5'' 4-1/2'' 4'' 3-1/2'' 3'' 5/8'' 7-1/2'' 6-7/8'' 6-1/4'' 5-5/8'' 5'' 4-3/8'' 3-3/4'' 3/4'' 9'' 8-1/4'' 7-1/2'' 6-3/4'' 6'' 5-1/4'' 4-1/2'' 7/8'' 10-1/2'' 9-5/8'' 8-3/4'' 7-7/8'' 7'' 6-1/8'' 5-1/4'' 1'' 12'' 11'' 10'' 9'' 8'' 7'' 6'' 1-1/4'' 15'' 13-3/4'' 12-1/2'' 11-1/4'' 10'' 8-3/4'' 7-1/2'' REDUCTION FACTOR - ANCHOR CAPACITY Tension/Shear 1.00 0.91 0.83 0.75 0.65 0.55 0.5 ANCHOR SPACING (E) in inches dia. = d 12d 11d 10d 9d 8d 7d 6d 1/4'' 3'' 2-3/4'' 2-1/2'' 2-1/4'' 2'' 1-3/4'' 1-1/2'' 5/16'' 3-3/4'' 3-1/2'' 3-1/8'' 2-7/8'' 2-1/2'' 2-1/4'' 1-7/8'' 3/8'' 4-1/2'' 4-1/8'' 3-3/4'' 3-3/8'' 3'' 2-5/8'' 2-1/4'' 1/2'' 6'' 5-1/2'' 5'' 4-1/2'' 4'' 3-1/2'' 3'' 5/8'' 7-1/2'' 6-7/8'' 6-1/4'' 5-5/8'' 5'' 4-3/8'' 3-3/4'' 3/4'' 9'' 8-1/4'' 7-1/2'' 6-3/4'' 6'' 5-1/4'' 4-1/2'' 7/8'' 10-1/2'' 9-5/8'' 8-3/4'' 7-7/8'' 7'' 6-1/8'' 5-1/4'' 1'' 12'' 11'' 10'' 9'' 8'' 7'' 6'' 1-1/4'' 15'' 13-1/4'' 12-1/2'' 11-1/4'' 10'' 8-3/4'' 7-1/2'' REDUCTION FACTOR - ANCHOR CAPACITY Tension 1.00 0.91 0.83 0.75 0.65 0.55 0.5 Shear 1.00 0.97 0.94 0.91 0.89 0.83 0.8 1. Use a carbide bit ANSI B212.15 (-1994) that is the same size as the bolt diameter. Drill hole deeper than bolt embedment (min.0.5 dia.) Do not use core bits. Maintain accurate hole size. 2. Clean hole of debris. 3. Add washer and thread nut 1/8" from the top of bolt. Drive bolt into hole through item to be fastened. 4. To set, tighten nut 3 to 4 full turns or consult chart for guide installation torque. A NEW F : 1- 8-252-6380 service@spaenaur. © 2018 Spaenaur Inc. All rights reserved. Catalog may not be reproduced, in whole or in part, without the written permission of Spaenaur Inc. Subject to Catalog Terms and Conditions of Use available at Spaenaur.com and on page TC2 and TC3 at the back of this catalog. © 2018 Spaenaur Inc. Tous droits réservés. Le catalogue ne peut être reproduit, en tout ou en partie, sans l’autorisation écrite de Spaenaur Inc. L’utilisation est soumise aux Conditions d’utilisation du Catalogue disponibles sur Spaenaur.com et à la page TC4 et TC5 à la fin de ce catalogue. CATALOG 14.01 2018/08/13

RkJQdWJsaXNoZXIy NzkyNDk4